Substation Automation Systems
P&C IEDs, RTUs, COMMUNICATIONS, SYSTEMS & SW
ZIV e-NET FLEX family suite:
all protection functions
ZIV IRL
Compact Feeder Multifunction solution for MV switchgear, with Load Shedding Function to ensure the stability of the system, Back-Up performing capability in HV lines and powerful built-in Control Logic Module.
ZIV IRS
Self-powered Overcurrent and Breaker Failure Protection Relay with Harmonic Blocking
NEW DISTRIBUTED BUSBAR
DIFFERENTIAL PROTECTION WITH PROCESS BUS
Line Differential Protection with Distance Backup
Both units are suitable for lines of any voltage level, overhead or under ground, multiterminal, and single or parallel circuits.
Distance Protection
Suitable for lines of any voltage level, single or double circuit breaker with any configuration: overhead or underground, single or parallel circuits
Transformer Protection
for two to four winding transformers or autotransformers, of any voltage level, with single or double circuit breaker.
Feeder Protection
IRF
for distribution feeders, transformers and generators, transmission line backup, and BCU (Bay Control Unit for single or double circuit breaker).
Where dependable auxiliary power source is not available, the IRS Relay can be energized either directly from Main Current Transformers, AC/DC Auxiliary Voltage or through the USB Front Port.
References & Homologations
References
IEDs certifed
Use cases
LATAM
EUROPE & AFRICA
IBERIA
ME
BRAZIL
INDIA
APAC
SAS Minglanilla
A Wind Farm Substation Automation System (30/132kV subst., 132kV line, Generation Subst. 132/400 kV, & evacuation line 400kV)
SAS
PE Campillo de Altobuey FI - 75 MW
PE Campillo de Altobuey FII – 87,5 MW
PE Campillo de Altobuey FIII – 87,5 MW
Wind Farms
PE Iniesta – 50 MW
PE Minglanilla I y II – 90 MW
REE Minglanilla
GECAMA Wind Farm – 300 MW
BARRA 1 132 kV
BARRA 2 132 kV
BARRA 1 400 kV
BARRA 2 400 kV
Wind Farm
+600MW
SAS | Chucena
SYSTEM INTEGRATION
Eg. Collector Substation
Electrical & Logical Engineering
IEDs supply + System integration + FAT + Commisioning
1
3
2
BARRA 2 400 kV
BARRA 1 400 kV
SET en coo-propiedad
MGE – CECSA
(2) SET CHUCENA – CECSA (DSO)
(3) SET CHUCENA – MGE (DSO)
INSTALACIÓN DE ENLACE,
LADO TRANSPORTE
IPP:
EPC:
Sas | Venalta
ZIV has equipped the new Venalta substation and a new line position for Huéneja (220kV).
A complete SAS for three solar parks capable of generating 150MW
SAS | Liister Drive Stability Project
A project in collaboration between the ZIV team of experts in Substation Control and RTUs located Newcastle (UK) and the experts in protection and control systems at ZIV headquarters. The project consisted in a connection of a Stabilizing Synchronous Condenser in the National Grid transmission system.
It included the protection and control of the transformer both for the 275Kv as for the 13,8kV part considering also the necessities of the controller of the SSC device itself. The direct client was the British company NRS Group and the owner of the project was the UK’s subsidiary of Nordic company Statkraft who accepted the ZIV IEDs, systems and communications protocols in the tendering phase.
SLD
System Architecture
16
IPP:
EPC:
SAS | Los Llanos I -II- III